Construction Chemicals
  1. Home
  2. Products
  3. Protective Coatings for Concrete and Steel in Construction
Product family

Protective Coatings for Concrete and Steel in Construction: Types and Selection

Product class data cardProtective coatings for concrete and steel
Chemistry base
acrylic, epoxy and novolac epoxy, polyurethane and polyurea, vinyl ester, ethyl silicate and zinc dust, calcium aluminate and geopolymer mortars
Forms
  • 1K water-borne
  • 2K solvent-borne
  • 2K 100 % solids
  • plural-component spray
  • and 2 more
Substrates
  • concrete
  • masonry and stucco
  • structural steel
  • ductile iron
  • hot-dip galvanized steel
Standards and classes
  • ISO 12944-1 to -9C1-C5, CX
Coverage or thickness
1,604 ft²/gal at 1 mil DFT (1,000 m²/L at 1 um (theoretical, dry film, arithmetic (231 in3 per US gal))
Application window
  • Substrate product-specific: -18 °C (0 °F) for ethyl silicate zinc up to 54 °C (130 °F) for 100 % solids epoxy
  • Dew point surface at least 3 °C (5 °F) above dew point
Cure times (typical)
Not recorded.
VOC limits
  • 100 g/L (0.83 lb/gal) SCAQMD Rule 1113, Industrial Maintenance (IM) Coatings
  • 450 g/L (3.8 lb/gal) US EPA AIM rule, 40 CFR 59 subpart D, Industrial maintenance coatings
  • 140 g/L EU Directive 2004/42/EC Annex II A, (j) two-pack reactive performance coatings (Phase II)
Hazards (typical)
H315, H317, H319, H411, H314 Check the product SDS.

Class-level values from standards, regulations and published data sheets, without product names. Check the data sheet and SDS of the product you use. Reviewed .

Protective coatings for concrete and steel are 7 product classes, from anti-carbonation and elastomeric wall coatings to chemical-resistant, sewer and potable-water linings and zinc-rich steel systems, that keep water, CO2, chlorides, chemicals and corrosion away from a structure. Each class is rated for a different exposure, so which one fits a facade, a manhole or a steel bridge?

The 7 classes form 3 groups: concrete protection coatings (sold in some markets as anti-carbonation paint), linings for immersion and chemical service (a containment lining is called a bund lining in the UK) and steel protection systems. Exterior concrete coatings on facades, car parks and bridges belong here; patio, driveway and floor coatings do not. Protective coatings are one of the 15 product families of construction chemicals.

ISO 12944 sets corrosivity categories from C1 to CX and durability up to more than 25 years for steel, EN 1504-2:2004 governs concrete, and VOC limits run from 100 g/L (0.83 lb/gal) in the South Coast air district to 450 g/L (3.76 lb/gal) under the federal EPA rule.

Standards, codes and regulations are checked against their issuing bodies, product values against the named data sheet and prices against the dated source named in the sentence; see our methodology and fact-checking.

What Is a Protective Coating for Concrete and Steel?#

A protective coating is a film or lining, applied in the field or the shop, that separates concrete or structural steel from water, CO2, chlorides, chemicals or sewer gas, and on steel may add galvanic protection. ISO 12944 calls the steel version a protective paint system, in 9 parts.

US VOC rules use the term industrial maintenance (IM) coating, defined by exposure such as immersion, chemicals or heat. Floor coatings, roof coatings, intumescent fire protection and clear penetrating sealers belong to other product families.

What does a protective coating system include?#

A protective coating system on steel has up to 4 parts, listed below.

  • Primer: adhesion plus galvanic or inhibitive protection.
  • Intermediate coat: barrier thickness, an epoxy in the standard system.
  • Topcoat: UV and weather resistance (aliphatic polyurethane, polysiloxane or fluoropolymer).
  • Stripe coats: extra coats on edges and welds, where corrosion starts when they are missing.

Concrete systems are a primer plus film coats; too little dry film from a missing coat is a recorded failure mode of anti-carbonation coatings.

How Do Protective Coatings Work?#

Protective coatings work in 2 ways: a barrier film or lining separates the substrate from the aggressive medium, and a zinc-rich primer adds galvanic protection to steel where the film is damaged. On concrete, the same barrier slows the CO2 and chloride ingress that lets reinforcement corrode.

Barrier films and linings#

A barrier coating protects only while the film is continuous, so pinholes, holidays and edges decide its life. Immersion linings are therefore holiday-tested before service (ASTM D4787-24 on concrete, D5162-24 on metal).

A novolac backbone raises the crosslink density of an epoxy for acids and solvents, vinyl ester resists hot acids, flake fillers lengthen the permeation path and glass mats add crack bridging. Recorded failure modes are blistering, disbondment, amine blush and cracking of rigid linings over moving cracks. Resin and hardener chemistry and skin sensitization are covered under epoxy resins.

Galvanic protection from zinc-rich primers#

Metallic zinc is anodic to steel, so a zinc-rich primer protects exposed steel galvanically while the zinc particles stay in contact. ISO 12944-5:2019 requires at least 80 % zinc dust by mass in the dry film of a Zn (R) primer; South Coast AQMD Rule 1113 defines a zinc-rich IM primer as containing at least 65 % metallic zinc by weight of total solids.

Ethyl silicate (inorganic zinc) cures by hydrolysis with air moisture, checked by MEK rubs to ASTM D4752-20(2024); epoxy and urethane zinc primers cure by their binder. Applied too thick, a zinc-rich primer mud-cracks.

Surface protection of concrete against CO2, water and chlorides#

On concrete, a coating slows the carbonation front and chloride ingress that let reinforcement corrode, while vapor-open grades let the wall dry. EN 1504-2:2004 names coating as 1 of its 3 surface protection systems.

A coating does not reverse carbonation already present: over carbonated cover left unrepaired, reinforcement corrosion continues under the new film. Carbonation depth testing and repair are covered under concrete carbonation.

7 Types of Protective Coatings in 3 Groups#

The 7 types of protective coatings fall into 3 groups: 2 concrete protection coatings, 3 linings for immersion and chemical service, and 2 steel protection systems. The group table below compares mechanism and thickness basis.

Group Classes Mechanism Thickness basis
Concrete protection coatings anti-carbonation, elastomeric wall film on exposed concrete and masonry, vapor-open DFT per coat
Linings for immersion and chemical service chemical-resistant and containment, sewer and manhole, potable water tank continuous barrier lining, holiday-tested DFT or mortar thickness
Steel protection systems zinc-rich primers, multi-coat steel systems galvanic primer plus barrier and topcoat system NDFT

1. Concrete protection coatings (2)#

Concrete protection coatings are films on exposed concrete and masonry that stay vapor-open; this group has 2 classes: anti-carbonation coatings and elastomeric wall coatings.

Anti-carbonation coatings#

An anti-carbonation coating is an acrylic dispersion or polymer-modified cementitious film that slows carbonation of concrete. EN 1504-2:2004 classes it under the coating method of surface protection. Facades, bridges and car parks with carbonation risk take it.

Elastomeric wall coatings#

An elastomeric wall coating is a high-build, water-borne 100 % acrylic film with a low glass transition temperature that bridges hairline cracks. ASTM D6904-03(2022) tests wind-driven rain resistance without pass/fail criteria, MPI #113 is its exterior water-based flat category, and EN 1062-7:2004 tests crack bridging.

2. Linings for immersion and chemical service (3)#

Linings for immersion and chemical service are continuous barrier linings, holiday-tested before service; this group has 3 classes: chemical-resistant and containment linings, sewer and manhole linings, and potable water tank linings.

Chemical-resistant and containment linings#

A chemical-resistant lining is a novolac epoxy or novolac vinyl ester film, flake or mat reinforced, for dikes, sumps, trenches and tanks. The containment rules 40 CFR 264.193 (hazardous-waste tanks) and 40 CFR 112.7(c) (oil) set the job the lining serves. Rigid linings crack over moving cracks.

Sewer and manhole linings#

A sewer lining is a 100 % solids epoxy or polyurea film, or a calcium aluminate, portland or geopolymer mortar, that resists biogenic sulfuric acid in manholes and wet wells. ASTM F2551-26 covers the mortar lining systems, and ASTM C1894-22 guides testing for microbially induced corrosion (MIC).

Potable water tank linings#

A potable water tank lining is an epoxy or elastomeric polyurethane lining certified to NSF/ANSI/CAN 61-2025 for its product and use conditions. ANSI/AWWA D102-24 governs coating of steel water-storage tanks, and the lining reaches full cure before the tank returns to service.

3. Steel protection systems (2)#

Steel protection systems combine a galvanic primer with barrier and topcoat layers specified by system NDFT; this group has 2 classes: zinc-rich primers and multi-coat steel systems.

Zinc-rich primers#

A zinc-rich primer is zinc dust in an ethyl silicate, epoxy or urethane binder. ISO 12944-5:2019 sets at least 80 % zinc dust in the dry film for a Zn (R) primer, and SSPC-Paint 20 (AMPP, 2019-12-01) divides the class into Type I inorganic and Type II organic.

Multi-coat steel systems#

A multi-coat steel system is a zinc primer, an epoxy intermediate and a polyurethane or polysiloxane topcoat built to a nominal dry film thickness. ISO 12944-2:2017, -5:2019, -6:2018 and -9:2018 set its corrosivity category, system design and laboratory tests.

Coatings covered in other product families#

Seven coating types protect concrete or steel but are selected in other product families, listed below. Patio, driveway and pool-deck coatings belong with exterior concrete sealers.

  • floor coatings: resin systems on slabs.
  • liquid roof coatings: films on roofs.
  • traffic coatings for parking decks: deck systems under vehicles.
  • intumescent coatings: fire protection of steel.
  • rebar corrosion protection coatings: primers on exposed reinforcement.
  • anti-graffiti coatings: layers on facades.
  • penetrating sealers: water repellents that form no film.

Acrylic, Epoxy, Polyurethane and Zinc Coatings Compared#

Acrylic, epoxy, polyurethane and zinc-rich coatings differ in job: acrylics protect exposed concrete and masonry while staying vapor-open, epoxies form barrier linings, polyurethanes give UV-stable topcoats and elastomeric linings, and zinc-rich primers protect steel galvanically. The verdict table below compares 5 chemistries by role, cure, weak point, EU VOC subcategory and hazard line.

Attribute Acrylic Epoxy (incl. novolac) Polyurethane and polyurea Zinc-rich Cementitious and calcium aluminate mortar
Role film on exposed concrete and masonry barrier lining, intermediate coat UV-stable topcoat, elastomeric lining galvanic primer on steel rebuilds manhole section
Cure coalescence of the dispersion reaction with an amine hardener isocyanate reaction ethyl silicate by air moisture, or binder cure hydration
Weak point cracks over dynamic cracks in cold climates chalks under UV; amine blush REACH entry 74 training for professional users mud-cracking above its film limit portland mortar loss in high-H2S service
EU 2004/42/EC subcategory (c) exterior walls of mineral substrate (j) two-pack performance (i) one-pack or (j) two-pack performance (i) or (j) where in scope not stated
Hazard line no Annex VI entry for the polymer class; see the product SDS liquid epoxy resin, Annex VI index 603-074-00-8: H315, H317, H319, H411 no Annex VI entry for the class; 4,4'-MDI (615-005-00-9) includes H334, H317; see the product SDS stabilised zinc dust, index 030-001-01-9: H400, H410 portland cement: no Annex VI entry, ECHA C&L notified H315, H317, H318, H335; calcium aluminate cement: no Annex VI entry; see the product SDS

Acrylic coatings for concrete#

Acrylic coatings for concrete are water-borne dispersions that form a film by coalescence and serve as anti-carbonation and elastomeric wall coatings. What separates an elastomeric acrylic from house paint?

The glass transition temperature: about -40 to -10 °C (-40 to 14 °F) against 0 to 25 °C (32 to 77 °F) for house paint, so the film stays rubbery and bridges hairline cracks (IIBEC class values). Below 1.0 perm a film acts as a vapor retarder, not a breather (IIBEC guidance). In the EU these coatings fall into subcategory (c), exterior mineral walls, at 40 g/L (0.33 lb/gal) water-borne. Binder types are explained under acrylic and styrene-acrylic polymers.

Epoxy linings and polyurethane topcoats#

Epoxy forms the barrier, polyurethane faces the weather: an epoxy intermediate chalks under UV, so steel systems finish with an aliphatic polyurethane, polysiloxane or fluoropolymer topcoat. Elastomeric polyurethane also lines potable water tanks.

For acids and solvents, novolac epoxy and novolac vinyl ester replace standard epoxy; vinyl ester cures by a free-radical reaction with a peroxide initiator.

Isocyanate chemistry brings a legal duty that epoxy does not: REACH Annex XVII entry 74 applies to polyurethane, polyurea and urethane-zinc coatings with 0.1 % or more diisocyanates by weight, not to epoxies. Isocyanate chemistry is covered under polyurethane resins.

Where Are Protective Coatings Used? Selection by Structure and Exposure#

Protective coatings are used on 7 kinds of structure, from exposed concrete facades and masonry walls to parking structures, bridges, water-retaining structures, sewers and chemical containment, and the exposure at each one sets the class. Exterior concrete coatings on structures are the anti-carbonation and elastomeric classes. The table below matches each structure with its exposure, classes and key document.

Structure Exposure Classes Key rule
Exposed concrete at risk of concrete spalling carbonation, chlorides anti-carbonation, elastomeric EN 1504-2:2004 coating method
Block, stucco and concrete walls (masonry waterproofing) wind-driven rain elastomeric wall ASTM D6904-03(2022), no pass/fail
parking structure waterproofing chlorides, traffic anti-carbonation on soffits and walls; deck coatings in another family SCAQMD Rule 1113 category by label
bridges, tunnels and marine structures C5, CX, Im2 multi-coat steel, zinc-rich, anti-carbonation ISO 12944-2:2017
water-retaining structures Im1 fresh water, potable contact potable linings, chemical-resistant NSF/ANSI/CAN 61-2025
Sewers and wastewater structures H2S, biogenic sulfuric acid sewer linings ASTM F2551-26
Chemical containment stored chemicals chemical-resistant 40 CFR 264.193

Facades, parking structures and bridges#

Exposed concrete on facades, car parks and bridges takes anti-carbonation or elastomeric coatings, chosen by crack movement and vapor drive. An anti-carbonation coating suits sound concrete where carbonation threatens the reinforcement, and an elastomeric wall coating suits block, stucco and concrete walls with hairline cracks and wind-driven rain. Parking deck surfaces under traffic take traffic coatings from another family, while soffits and walls take anti-carbonation coatings.

Water tanks, sewers and containment areas#

Tanks, manholes and chemical containment take linings rated for immersion, acid or stored chemicals, and each is holiday-tested before service. A potable lining carries an NSF/ANSI/CAN 61-2025 listing for its use conditions, a sewer lining resists biogenic sulfuric acid, and a containment lining serves a dike or vault sized under 40 CFR 264.193.

Water treatment chemistry, including NSF/ANSI/CAN 60 treatment chemicals and H2S control, is a separate topic, not covered here.

Structural steel, towers and marine structures#

Structural steel takes a zinc-rich primer, an epoxy intermediate and a weather-resistant topcoat, with total film build rising with corrosivity category and durability. Offshore steel in category CX needs a system of at least 280 µm (11 mils) NDFT with a Zn (R) primer under ISO 12944-9:2018, qualified by 4,200 h of cyclic ageing in 25 weekly cycles.

Which Standards Govern Protective Coatings?#

Protective coatings are governed in 3 layers: ISO 12944 for paint systems on steel, EN 1504-2:2004 for surface protection of concrete, and US documents for specific services, with ASTM and ISO test methods for inspection. The US service documents are NSF/ANSI/CAN 61-2025, ANSI/AWWA D102-24, ASTM F2551-26 and 40 CFR 264.193.

Corrosivity categories and durability ranges for steel#

ISO 12944-2:2017 classes atmospheres from C1 to C5 plus CX offshore and immersion from Im1 to Im4, replacing the pre-2017 labels C5-I and C5-M. Im1 is fresh water, Im2 sea or brackish water, Im3 soil and Im4 sea or brackish water with cathodic protection.

ISO 12944-1:2017 plans durability as low (up to 7 years), medium (7 to 15), high (15 to 25) or very high (more than 25), not a guarantee time. Under ISO 12944-6:2018, C5 very high needs 2,688 h of cyclic ageing; C4 very high and C5 high accept 1,680 h cyclic or 720 h condensation plus 1,440 h salt spray. Test hours per category are tabled under ISO 12944.

ISO 9223:2012 puts first-year carbon steel corrosion in C5 at 80 to 200 µm (3.1 to 7.9 mils) per year. ISO 12944 parts 1, 2, 3, 5, 6, 7 and 8 stand at stage 90.92, to be revised, with no new edition as of 2026-10-22.

Surface protection standards for concrete#

EN 1504-2:2004 covers 3 surface protection systems for concrete: hydrophobic impregnation, impregnation and coating. Anti-carbonation and elastomeric products are declared under the coating method.

EN 1062-7:2004 tests crack bridging of exterior masonry and concrete coatings by method A (static) and method B (dynamic). ASTM D6904-03(2022) sprays coated block under air pressure equal to a 98 mph (158 km/h) wind and sets no pass/fail criteria, so a resistance claim names the maker's own limit. Declared properties are explained under EN 1504-2.

Potable water, sewer and containment documents#

NSF/ANSI/CAN 61-2025 certifies that a lining does not leach contaminants above health-based limits; it is not a performance rating. The listing states the use conditions that the job must match.

ANSI/AWWA D102-24 (superseding D102-21) governs coating of steel water-storage tanks. ASTM F2551-26 covers manhole rehabilitation with cementitious (portland or calcium aluminate) or geopolymer mortar linings; ASTM F2414-04(2023) covers chemical grouting, not coatings. Under 40 CFR 264.193 an external liner holds 100 % of the largest tank plus the 25-year, 24-hour rainfall, and a release is detected and removed within 24 h.

Test methods for adhesion, continuity and film build#

Five test methods check a coating on site, listed below.

  • pull-off adhesion testing: ASTM D7234-22 on concrete.
  • ISO 12944-6:2018 pull-off levels: systems over 250 µm (9.8 mils) need at least 2.5 MPa (363 psi) on unexposed panels (KTA summary).
  • holiday testing of coatings and linings: ASTM D4787-24 on concrete, ASTM D5162-24 on metal (wet sponge or high-voltage spark).
  • ISO 29601:2026: porosity of a dry film on metal.
  • coating thickness measurement: ISO 25014:2026 on concrete cross sections.

How Thick Is a Protective Coating System? Dry Film, Wet Film and Coverage#

Protective coating systems are specified by nominal dry film thickness (NDFT): offshore CX systems under ISO 12944-9:2018 need at least 280 µm (11 mils) with a zinc-rich primer, and each coat's dry film equals its wet film times its volume solids. With other primers the CX minimum rises to 350 µm (13.8 mils), as summarized by AkzoNobel.

Wet film, dry film and volume solids#

Dry film thickness equals wet film thickness times volume solids, so a 60 % solids coat applied at 208 µm (8.2 mils) wet dries to 125 µm (4.9 mils); a 100 % solids coating dries to its wet thickness.

Theoretical coverage is 1,604 ft² per US gallon at 1 mil (25.4 µm) DFT and 100 % volume solids, or m²/L = 1,000 × volume solids / DFT in µm. Worked example 1 (inputs: 100 % solids, 500 µm (19.7 mils) DFT): 2.0 m²/L (81.5 ft²/gal). Worked example 2 (inputs: 60 % solids, 125 µm DFT): 4.8 m²/L (196 ft²/gal). Other values can be run in the coating coverage calculator.

Practical coverage is lower by the loss factor, so a coverage figure states theoretical or practical, per coat and at which DFT.

Surface preparation and application conditions#

Coatings go onto a surface at least 3 °C (5.4 °F) above the dew point, measured on the substrate (ISO 8502-4:2017). ISO 12944-2:2017 counts steel corrosion as significant above 80 % relative humidity and above 0 °C (32 °F).

On concrete, moisture limits are the product maker's: ASTM F2170-19a and F1869-23 measure moisture and set no pass/fail. Profile grades for concrete are explained under concrete surface profile.

ISO 12944-6:2018 qualifies steel systems on panels blast-cleaned to Sa 2½ with a medium (G) profile; ASTM D4417-21 measures blast profile in the field.

VOC Limits and Safety Rules for Protective Coatings#

VOC limits for protective coatings depend on jurisdiction and category, from 100 g/L (0.83 lb/gal) for industrial maintenance coatings in the South Coast air district to 450 g/L (3.76 lb/gal) under the federal EPA rule. Safety rules add harmonised hazard lines for resins and zinc dust, diisocyanate training and silica limits for grinding and blasting.

VOC limits by jurisdiction#

The South Coast AQMD Rule 1113, as amended 2016-02-05, treats coatings for immersion, chemical exposure, heat above 121 °C (250 °F), heavy abrasion or exterior metal as industrial maintenance coatings at 100 g/L (0.83 lb/gal). Above 204 °C (400 °F), high-temperature IM coatings carry 420 g/L (3.51 lb/gal). Every category is listed under VOC limits for construction chemicals.

The federal EPA AIM rule (40 CFR 59 subpart D) judges compliance on g/L and has no zinc-rich category; EU Directive 2004/42/EC Phase II limits apply to the ready-to-use product. The table below compares the 3 regimes for 8 categories in g/L (lb/gal).

Category SCAQMD Rule 1113 (amended 2016-02-05) EPA AIM (made on or after 1999-09-13) EU 2004/42/EC Phase II (since 2010-01-01)
Industrial maintenance coatings 100 (0.83) 450 (3.76) see note below
Zinc-rich IM primers 100 (0.83) no category: IM 450 (3.76) or primers and undercoaters 350 (2.92) see note below
Concrete protective coatings not stated 400 (3.34) (c) exterior mineral walls WB 40 (0.33) / SB 430 (3.59)
Flats; nonflats (exterior wall coatings) 50 (0.42); 50 (0.42) flat exterior 250 (2.09); nonflat exterior 380 (3.17) (c) WB 40 (0.33) / SB 430 (3.59)
Building envelope coatings 50 (0.42) since 2019-01-01 not stated not stated
Primers, sealers and undercoaters 100 (0.83) primers and undercoaters 350 (2.92) (g) primers WB 30 (0.25) / SB 350 (2.92)
Rust preventative coatings 100 (0.83) 400 (3.34) not stated
High-temperature IM (above 204 °C (400 °F)) 420 (3.51) high temperature coatings 650 (5.42) not stated

EU (i) one-pack and (j) two-pack performance coatings: WB 140 (1.17) / SB 500 (4.17) g/L ready to use, for coatings on buildings and associated structures within the Directive's scope.

Epoxy, diisocyanate, zinc and silica rules for applicators#

Liquid epoxy resin carries a harmonised classification (CLP Annex VI index 603-074-00-8): H315, H317, H319, H411. Hardeners add more: IPDA (612-067-00-9) carries H302, H314, H318, H317, and TETA (612-059-00-5) carries H312, H314, H317, H412.

REACH Annex XVII entry 74 (Regulation (EU) 2020/1149) covers products with 0.1 % or more diisocyanates by weight: label statement since 2022-02-24, user training since 2023-08-24, renewed at least every 5 years. 4,4'-MDI (615-005-00-9) carries H351, H332, H335, H373, H315, H319, H334, H317. Training duties are set out under diisocyanates rules.

Stabilised zinc dust (030-001-01-9) carries H400, H410; the pyrophoric grade (030-001-00-1) adds H250, H260. Ethyl silicate (014-005-00-0) carries H226, H319, H332, H335. Portland cement: no Annex VI entry; ECHA C&L notified classification: H315, H317, H318, H335; see the product SDS. Calcium aluminate cement: no Annex VI entry; see the product SDS. Respirable crystalline silica falls under OSHA 29 CFR 1926.1153 (effective 2016-06-23: PEL 50 µg/m³ 8-h TWA, action level 25 µg/m³) and the EU limit of 0.1 mg/m³ (Directive (EU) 2017/2398).

Complete List of Protective Coatings: All 7 Classes#

The complete list below gives all 7 protective coating classes with their chemistry, US and European or international standards, typical use, applicator need and a dated installed cost where a public bid gives one.

Class Chemistry US basis EU / international basis Typical use Applicator Installed cost (dated)
anti-carbonation coatings for concrete acrylic dispersion; polymer-modified cementitious no ASTM product standard; ASTM D7234-22 pull-off EN 1504-2:2004 (coating) facades, bridges, car parks depends not published
elastomeric wall coatings low-Tg 100 % acrylic, water-borne ASTM D6904-03(2022) (no pass/fail); MPI #113 EN 1062-7:2004 (crack-bridging test) block, stucco, above-grade concrete depends not published
chemical-resistant linings and secondary containment coatings novolac epoxy, novolac vinyl ester, flake or mat reinforced 40 CFR 264.193; 40 CFR 112.7(c); ASTM D4787-24 none stated dikes, sumps, trenches, tanks yes not published
sewer manhole and wet-well linings 100 % solids epoxy, polyurea; calcium aluminate or geopolymer mortar ASTM F2551-26 (mortar); ASTM C1894-22 (MIC guide) none stated manholes, wet wells, headworks yes installed, public bid tabulation: epoxy liner USD 912 to 1,476 per vertical m (USD 278 to 450 per vertical ft); cementitious liner USD 545 to 656 per vertical m (USD 166 to 200 per vertical ft); Ann Arbor MI, 2018-05
coatings for potable water tanks and reservoirs polyamidoamine or 100 % solids epoxy, elastomeric polyurethane, zinc plus epoxy NSF/ANSI/CAN 61-2025; ANSI/AWWA D102-24 none stated steel and concrete tanks, reservoirs yes installed, public bid tabulation: elevated tank interior (zinc plus 100 % solids epoxy) USD 90,000 to 132,640 lump sum per tank, 10 bids, Ohio, 2024
zinc-rich primers for structural steel zinc dust in ethyl silicate, epoxy or urethane SSPC-Paint 20 (AMPP 2019-12-01); SCAQMD Rule 1113 at least 65 % zinc ISO 12944-5:2019 Zn (R) at least 80 % primer of steel systems yes not published
anti-corrosion coating systems for structural steel zinc primer plus epoxy plus polyurethane, polysiloxane or fluoropolymer no single product standard; ASTM D4417-21, D5162-24 ISO 12944-2:2017, -5:2019, -6:2018, -9:2018 structural steel, bridges, towers yes installed, public bid tabulation: elevated tower exterior (zinc, urethane, fluoropolymer) USD 100,000 to 310,000 lump sum per tower, 10 bids, Ohio, 2024

Lump sums are public bids for one project each; tank and tower areas were not stated. Material-only kit prices are not shown.

The costs are installed public bid tabulations: Ann Arbor, Michigan, May 2018, and Ohio, 2024. Public procurement records show what buyers paid at a given date and place; they include delivery and local terms and are not a current price. For the other 4 classes, price depends on area, access, preparation and exposure.

Which Protective Coating Is Best for a Structure?#

No protective coating is best for every structure: the right class is the one rated for the exposure, the substrate and the durability required, named in the specification by standard and category, not by brand. A steel bridge girder in category C5 with a very high durability target needs a system qualified by 2,688 h of cyclic ageing to ISO 12944-6:2018, while a carbonating concrete facade needs an EN 1504-2:2004 coating that stays vapor-open.

Can protective coatings go on damp concrete?#

Only where the product data allows it: moisture limits are set by each maker, and ASTM F2170-19a and F1869-23 measure moisture without setting a pass/fail. The 2 moisture methods are compared under concrete moisture testing.

How long does a protective coating last?#

ISO 12944-1:2017 plans durability in 4 ranges, from low (up to 7 years) to very high (more than 25 years), and states that durability is not a guarantee time. A system tested to C5 very high under ISO 12944-6:2018 also suits lower categories.

What destroys concrete in sewers and wastewater structures?#

Sulfuric acid formed by bacteria from hydrogen sulfide destroys concrete in sewers; the EPA reported losses of 0.25 to 4.3 mm (0.01 to 0.17 in) per year in Los Angeles County. Sulfate-reducing bacteria produce sulfide, hydrogen sulfide (H2S) escapes to the headspace, and Thiobacillus oxidizes it to sulfuric acid on moist walls (EPA Report to Congress 430/09-91, 1991).

Is a concrete sealer a protective coating?#

Not always: a penetrating sealer works inside the pores and forms no film, while a protective coating forms a continuous film or lining on the surface. Sealer types and their limits are compared under concrete sealers.

Do protective coatings need a specialist applicator?#

Most do: 5 of the 7 classes need a trained applicator for confined spaces, plural-component spray and holiday testing, and EU users of diisocyanate products need documented training. Anti-carbonation and elastomeric wall coatings go on by brush, roller or airless spray, but bridges, car parks and high-rise facades take a specialist contractor.

Is hot-dip galvanizing a protective coating?#

It is a metallic coating applied in a galvanizing plant, an alternative to a zinc-rich primer, not a coating applied on site. Paint over galvanizing forms a duplex system.